CBRSB - 15A TRANSMISSION LEAK STOP

  • MSDS: CBRSB
  • Manufacturer: SILOO
  • Product Name: 15A TRANSMISSION LEAK STOP
  • National Stock Number: 6850-00D005497
Product Identification

Product ID:15A TRANSMISSION LEAK STOP
MSDS Date:03/01/1990
FSC:6850
NIIN:00D005497
MSDS Number: CBRSB

Responsible Party
SILOO
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: A. B. REED

Cage: SILOO

Contractor
SILOO
2549 WARMINSTER, PA 18974 US

Telephone: 215-674-4300

Cage: SILOO

Ingredients

MINERAL OIL

CAS: 64742-54-7

RTECS: PY8035500

Fraction By Weight: 80.1%

OSHA PEL 5 MG/M3 (OIL MIST)

ACGIH TLV: 5 MG/M3 (OIL MIST)


XYLENES (O-,M-,P- ISOMERS) (SARA 313) (CERCLA)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 9.0%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM/150STEL;9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TRANSMISSION ADDITIVE

Fraction By Weight: 10.9%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY CAUSE BURNING & IRRIT OF
EYES. SKIN CONTACT WILL CAUSE DRYNESS. INHALATION OF MSIT MAY CAUSE
BREATHING PROBLEMS. VAPORS MAY ALSO CAUSE HEADACHES & NAUSEA.
CHRONIC:PROLONGED EXPOSURE TO SKIN MAY CAUSE DEVELOPMENT OF
DERMATITIS.
Explanation of Carcinogenicity:PER MSDS:CHEMICAL LISTED AS CARCINOGEN
OR POTENTIAL CARCINOGEN:NTP/IARC/OSHA:NO.
Effects of Overexposure:BURNING & IRRIT OF EYES. SKIN DRYNESS.
BREATHING PROBLEMS. HEADACHES, NAUSEA. DERMATITIS.

First Aid

First Aid:IF SYMPTOMS PERSIST CALL PHYSICIAN. INHAL:REMOVE TO FRESH
AIR. APPLY ARTIFICIAL RESPIRATION IF NEEDED. EYE:FLUSH FOR 15MINS
W/LG AMTS OF WATER. SKIN:REMOVE CONTAMIN CLOTHING. WASH EXPO SKIN
W/SOAP/WAT ER. INGEST:DO NOT INDUCE VOMITING. CALLDOCTOR.

Fire Fighting

Flash Point Method:TOC
Flash Point:275F,135C
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, FOAM.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:TREAT AS OIL FIRE.

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE ANY SOURCES OF
IGNITION. DIKE AREA & ABSORB W/SAND OR OTHER ABSORBANT. SCRAPE UP &
PLACE IN DRUMS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL DRY AREA.
Other Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN USE. SPILLS SHOULD
BE KEPT OUT OF STREAMS OR WATER SUPPLY.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATORS FOR HIGH MSIT
CONCENTRATION.
Ventilation:ADEQUATE VENITLATION TO MAINTAIN OIL MIST BELOW PEL IF
SPRAYED.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:OIL RESISTANT APRONS, BOOTS, ETC SHOULD BE
WORN IF OTHER PARTS OF BODY ARE SUBJECT TO EXPOSURE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. HMIS:WASH HANDS
AFTER HANDLING.LAUNDRY CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NA
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:0.8727
pH:NP
Evaporation Rate & Reference:NA
Solubility in Water:NEGLIGIBLE.
Appearance and Odor:REDDISH COLORED LIQUID.
Percent Volatiles by Volume:9.0
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:SOURCES OF IGNITION.
Hazardous Decomposition Products:CO2, CARBON MONOXIDE (THERMAL).

Disposal

Waste Disposal Methods:COMPLY W/FED/STATE/LOC REGULATION FOR OIL WASTE
MATLS. CHEMS FOUND IN SEC 313 OF EPCRA SARA TITLE III & SUBJ TO
RELEASE INVENTORY REPORTING:XYLENE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.